Back to top
Fish Insulating Paper
Fish Insulating Paper

Fish Insulating Paper

MOQ : 10 Tons

Fish Insulating Paper Specification

  • Density
  • 1.2 Gram per cubic centimeter(g/cm3)
  • Shelf Life
  • 12 months
  • Width
  • Up to 1000 mm
  • Length
  • Custom roll lengths
  • Thermal Conductivity
  • Low (insulating)
  • Operating Temperature
  • Up to 105C
  • Thickness
  • 0.2 mm to 1.0 mm
  • Product Type
  • Insulating Paper / Fish Paper Roll
  • Application
  • Electrical insulation in transformers, motors, and other electrical equipment
  • Material
  • Fish Paper (Vulcanized fiber) / cellulose fiber
  • Rated Voltage
  • Up to 1.2 kV
  • Tensile Strength
  • 120 MPa
  • Function
  • Electrical insulation, heat resistance
  • Heat Resistance
  • Good
  • Paper Core
  • Yes
  • Weight
  • Varies with size
 

Fish Insulating Paper Trade Information

  • Minimum Order Quantity
  • 10 Tons
  • Payment Terms
  • Cheque
  • Supply Ability
  • 300 Tons Per Month
  • Delivery Time
  • 7-10 Days
  • Packaging Details
  • Standard Packaging
  • Main Domestic Market
  • All India
 

About Fish Insulating Paper

Our company is one of the leading manufacturers and suppliers of Fish Insulating Paper. It is a durable, flexible, electrical insulator which is made of vulcanized fiber and used with motor windings and for gasket insulation. Before the final dispatch, it is checked on different standard parameters by our experts in order to deliver defect free range. It is a lightweight dielectric paper which is also a good choice for oil-filled transformers. Known for its high strength and optimum thickness, this Fish Insulating Paper is provided in safe packaging to avoid dirt and dust during transit.

Fish Insulated Paper:

We are one of the leading manufacturers of different range of fish Insulated papers. These fish paper are used in different industrial uses. These fish papers are available in different sizes and range as per client requirements.



Superior Electrical Insulation

Fish Insulating Paper is engineered to provide outstanding electrical insulation due to its high dielectric strength of 18 kV/mm. Its low thermal conductivity and moisture absorption enhance safety and improvement in transformer, motor, and switchgear performance. The smooth, flexible surface enables easy fabrication and reliable application across a variety of electrical components.


High Durability and Resistance

With a tensile strength of 120 MPa and high resistance to acids, this paper ensures longevity and durability under operational electrical stresses. Its low flammability and heat resistance up to 105C make it a safe choice for installations requiring robust insulation materials.


Versatile Sizing and Easy Storage

Available in rolls or sheets up to 1000 mm wide and in thicknesses from 0.2 mm to 1.0 mm, Fish Insulating Paper supports custom requirements for unique applications. It must be stored in dry conditions away from sunlight to maintain its performance and shelf life of 12 months.

FAQs of Fish Insulating Paper:


Q: How is Fish Insulating Paper typically used in electrical applications?

A: Fish Insulating Paper is widely used as an insulating medium in transformers, motors, and various electrical components. Its dielectric strength and flexibility allow it to be wrapped, layered, or cut to fit specific parts, providing reliable insulation and heat resistance.

Q: What are the primary benefits of using this paper in electrical equipment?

A: The main advantages include high dielectric strength, excellent acid resistance, low moisture absorption, and a smooth, flexible surface. These properties help prevent electrical breakdowns and extend the lifespan of equipment.

Q: When should this insulating paper be replaced or checked for quality?

A: It is recommended to inspect the paper during routine electrical maintenance. Due to its 12-month shelf life, unused stock should be checked annually for signs of moisture absorption or physical degradation.

Q: Where can Fish Insulating Paper be sourced in India?

A: This insulating paper is available through leading importers, manufacturers, suppliers, and traders across India. Custom roll lengths and sheet sizes can be ordered to meet specific industrial needs.

Q: What is the correct storage condition for this product?

A: Fish Insulating Paper should be stored in a dry place away from direct sunlight to prevent moisture absorption and ensure it maintains its insulating properties throughout its shelf life.

Q: How is the material processed for installation in equipment?

A: The paper is typically cut or shaped as per requirement, using its smooth edges for a precise fit. Its flexibility allows easy wrapping or layering around conductors, coils, or windings, suited for both automated and manual assembly processes.

Q: What ensures the safety of this material during operation?

A: Its low flammability, high acid resistance, and reliable performance at operating temperatures up to 105C contribute to safety. The thickness tolerance and smooth, odorless finish further support professional electrical insulation standards.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fish Insulated Paper Category

Insulation Fish Paper

Insulation Fish Paper

Minimum Order Quantity : 10 Kilograms

Thickness : 0.13 mm 0.45 mm

Heat Resistance : Other, Class A (105C)

Application : Electrical insulation, slot liners in motors, transformers, and other electrical devices

Length : Variable (customized as per requirement; typically 50 m or 100 m per roll)

Tensile Strength : 60 N/10 mm 90 N/10 mm

Insulation Fish Papers

Insulation Fish Papers

Minimum Order Quantity : 10 Tons

Thickness : 0.13 mm to 0.80 mm

Heat Resistance : Other, Class A (Up to 105C)

Application : Electrical insulation and transformer winding insulation

Length : 5 m, 10 m, 50 m roll

Tensile Strength : 80 N/10mm

Slitted Insulation fish paper

Slitted Insulation fish paper

Minimum Order Quantity : 10 Tons

Thickness : 0.2 mm to 1.0 mm

Heat Resistance : Other, Good, withstands high temperatures

Application : Electrical insulation in transformers, motors, coils, capacitors, and switchgear

Length : Custom lengths available, standard rolls up to 100 meters

Tensile Strength : 125 MPa